Set-Up Instructions- STAT IV 1000 Large Animal I.V. Set Page 2
Step Five
Write the date and time on set-up and patient name on the patient label.
Step Six
Prime the I.V 1000 Set by opening the blue on/off clamps. Once primed either close the white on/off clamp on the coil or close the screw flow control clamp.
Step Seven
Place the third and fourth fluid containers on the high hooks of the GYRO Fluid Hanger.
Step Eight
To interconnect the additional fluid containers a Transfer Set (TS2001) is used.
Important! First close the blue on/off clamp on the Transfer Set.
Step Nine
Insert the piercing pin into the outlet port on the fluid container.
Insert the other piercing pin on the Transfer Set into the second outlet port on one of the low fluid containers also connected to the IV1000.
Open the blue on/off clamp to initiate fluid transfer.